Coriolis meters manufacturer today

High quality coriolis flow meters supplier: In terms of cost, electromagnetic flow meters are more affordable than mass flow meters. The cost of electromagnetic flow meters is moderate. It is suitable for more users. Mass flow meters have higher measurement accuracy, but they are also more expensive. For customers with specific needs. What is mass flow meter? Measures Mass Flow: A mass flow meter measures the mass passing through a pipe or conduit in a specified amount of time. The unit of measurement is typically kilograms per second (kg/s) or another mass-related unit. Discover more information on coriolis mass flowmeter.

Second, the gas turbine flow meter equipment has strong functions, low power consumption and superior performance. When it is sold in the industry, it is found that the functional advantages of this kind of flowmeter will be more perfect. In many gas distribution stations or gas When promoting in the station, I found that the advantages will be more diversified, and there are more and more advantages. Third, the configuration of the natural gas turbine flow meter instrument is more perfect, and it will be more and more widely used. As long as you take a fancy to the above clarity, it will be more convenient in the process of normal use. After this is used in many gas distribution stations, it is found that the measurement accuracy is higher.

To calculate the steam mass flow from the frequency signal output by the frequency output vortex flowmeter, you only need to know the current working condition of the fluid, while the temperature and pressure compensation of the analog output vortex flowmeter is only the error caused by the deviation of the current working condition from the design working condition. Compensation, therefore, not only need to know the current conditions, but also need to know the design conditions. The data of the latter working condition often causes errors due to the loss of data due to the passage of time or personnel changes. In contrast, the frequency output vortex flowmeter does not have this problem.

China Capital technology group invested in the SINOPEC automation instrument department of Beijing institute of chemical industry. Beijing shouke shí huà automatic equipment Co., LTD (Beijing Sincerity’s predecessor) was officially established. “Shí huà” is the Chinese words from SINOPEC. Sincerity officially switched from a national company to joint-stock company. Beijing shouke shí Huá ( which is Beijing Sincerity Automatic Equipment Co., Ltd now ) was officially established. The Chinese pronunciation of “shí Huá “ and “ shí huà” are very close to each other. The 1st generation coriolis mass flow meters were officially launched. The coriolis mass flow meters are with all discrete components, little chips and LED digital display.

The coriolis flow meter consists of a sensor and a transmitter. The coriolis mass flow meter is equipped with digital signal processor (DSP) -based digital transmission equipment, and integrates digital closed-loop vibration control (DLC) signal processing, sensor calculation and diagnostic functions, and has high measurement accuracy and extensive capabilities. And excellent reliability for you. On-line node configuration, fault diagnosis and data logging can be performed directly through HART or PC via Modbus to communicate with the communicator. The flow meter will not only calculate the process volume flow, cumulative volume and component ratio. TS series flow meters can also provide coriolis gas flow meter, density and temperature online in real time. See more info on https://www.bjssae.com/.

Beijing Sincerity is the leader of the coriolis mass flow meters industries in China,who specialized in producing thermal mass flow meter,turbine flow meter,fork density meters and ultrasonic flow meter. In line with our collaborative approach to our customers we are also able to discuss tailor-made Service and Support Solutions designed specifically for your needs that can include such topics as training, instrument replacement agreements and instant service and repair.

Install the total steam flow meter before the pressure reducing valve. Since the above-mentioned steam has not been decompressed, there is no phase change problem, so install the flowmeter before the pressure reducing valve, and use the saturated steam compensation method to ensure the measurement Accuracy. If the flowmeter can only be installed behind the pressure reducing valve, a pressure transmitter can be added for temperature and pressure compensation. If the stability of the pressure reducing valve is good, the upstream pressure value of the flowmeter can be set as a constant value in the display instrument for temperature and pressure compensation.